- Material: (Housing) Stainless steel AISI 430, (Interior) Stainless steel AISI 304
- 2 doors, self-closing, lockable, with practical magnetic seal
- 6 height-adjustable shelves (W 530 x D 650 mm), load capacity per shelf: distributed up to approx. 25 kg
- Grate adjustment: Up to 80 mm spacing possible
- Various insertion options for the racks thanks to notches in the side wall
- 2 floor grates (W 538 x D 630 mm) for optimal, energy-reducing air circulation
- 4 height-adjustable feet
- Digital temperature control (DIXELL)
- Insulation: 90 mm
- Forced air cooling with highly efficient fan and optimal airflow
- Automatic fan shutdown system when door is opened
- Automatic defrosting and automatic evaporation of condensate
- Suitable for climate classes 4 and 5
- Temperature range: -2 / +8 °C
- Connection: 230 V - 50 Hz - 0.130 kW
- Grates: 3x W 530 x D 650 mm + for floor: W 510 x D 605 mm
- Capacity (gross/net): 1300 / 940 liters
- Internal dimensions: W 1240 x D 700 x H 1501 mm
- External dimensions: W 1420 x D 875 x H 2090 mm
- Weight (net/gross): 198 / 213 kg
- Refrigerant: R600a
- Energy efficiency class: A (spectrum A+++ to G) in climate class 5
-> High-performance device!
- On-site service
____________________________
Safety and warning instructions
- Place the device only on a stable, level surface.
- Ensure that the mains voltage matches the specifications on the nameplate.
Children and unauthorized persons must not operate or misuse the device.
- Never clean the device with a water jet to avoid the risk of short circuits.
- After transporting the device, it must stand upright for at least 24 hours before being switched on to prevent damage to the refrigerant circuit.
- The device must not be operated near heat sources, direct sunlight or in damp rooms.
- For adequate ventilation, maintain a distance of at least 10 cm to the back wall and 30 cm upwards.
- The ventilation area must always be free of dust and obstructions to ensure optimal cooling performance.
- The refrigerant is flammable – damage to the cooling system must be avoided at all costs, and in case of a leak, the room should be well ventilated. Avoid open flames or sparks.
- In case of visible damage or malfunctions, stop operation immediately and contact the specialist dealer.
- Before any cleaning, maintenance or prolonged non-use, unplug the appliance and allow it to defrost completely.
- The condenser slots should be cleaned regularly to remove dust deposits and maintain efficiency.
- Repairs and maintenance work may only be carried out by qualified specialists.